NHXH E90 - Halogen Free, Concentric Conductor Cable

Untitled-1 copy

NHXH E90 - Halogen Free, Concentric Conductor Cable

(N)HXCH FE180/E30 KERAM | Halogen Free, Concentric Conductor Cable - 30 min Circuit Integrity, 180 min Insulation Integrity

Product Descriptions

Implementation:

Suitable for indoor and outdoor installations where safety of people and equipment is critical and where high fire protection and damage resistance are required. Cannot be laid directly in soil or water. Circuit integrity provides 30 minutes protection and insulation integrity provides 180 minutes protection.

Information:

Meets 180 min insulation integrity test requirements according to DIN VDE 0472-814/8.83 and 30 min circuit integrity test requirements according to IEC Publ. 331 (1970) and DIN 4102-12 (VDE 0100-710/-718) and 30 min circuit integrity test requirements.

Structure

  • Solid or stranded bare copper conductor
  • Core isolation: Halogen-free, ceramic-like polymer compound (HXI 1)
  • Halogen-free inner sleeve
  • Concentric conductor: Helically wound copper wires and copper tape wound in an opposite helix
  • Outer sheath: Halogen-free polymer (HM 4), orange

Standards

  • DIN VDE 0266
  • DIN VDE 0276-604
  • DIN VDE 0472-814
  • DIN EN 60228 Class 1 and 2
  • HD 308 S2 (conductive color coding)

Technical Data

  • Nominal Voltage U₀/U [V]: 600 / 1000
  • Test Voltage AC [V]: 4000
  • Temperature Range (moving): -5 °C ... +90 °C
  • Short Circuit Operating Temperature [°C]: 250
  • Short Circuit Time (max.) [s]: 5
  • Bending Radius (moving, diameter ×): 12
  • Flame Resistance Standard: EN 50266-2-4 - IEC 60332-3 Cat. C
Number of Cores and Cross Section (mm²) Copper Quantity (kg/km) Outer Diameter (mm) Calorific Potential (kWh/m) Weight (kg/km)
1 × 16 RM 153,60 10,5 0,42 250
1 × RM 25 240,00 12,5 0,53 355
1 × RM 35 336,00 13,5 0,60 460
1 × RM 50 480,00 15,0 0,69 596
1 × RM 70 672,00 16,5 0,83 810
1 × RM 95 912,00 19,0 1,06 1.100
1 × 120 RM 1.152,00 20,5 1,15 1.350
1 × RM 150 1.440,00 22,5 1,38 1.650
1 × RM 185 1.776,00 25,0 1,68 2.050
1 × 240 RM 2.304,00 28,0 1,84 2.650
1 × RM 300 2.880,00 31,0 2,18 3.275
2 × 1.5 RE 28,80 14,3 0,69 275
2 × 2.5 RE 48,00 14,9 0,78 320
3 × 1.5 RE 43,20 15,0 1,02 315
3 × 2.5 RE 72,00 15,9 1,12 371
3 × 4 RE 115,20 16,7 1,21 435
3 × 6 RE 172,80 17,8 1,34 526
3 × 10 RE 288,00 19,5 1,54 691
3 × 16 RM 460,80 22,3 1,90 982
3 × RM 25 720,00 25,8 2,48 1.392
3 × 35 RM 1.008,00 28,4 2,87 1.778
3 × 35/16 RM 1.161,60 29,5 3,06 1.964
3 × 50/25 RM 1.680,00 33,6 3,94 2.633
3 × 70/35 RM 2.352,00 38,1 4,81 3.563
3 × RM 95/50 3.216,00 43,4 6,16 4.768
3 × 120/70 RM 4.128,00 46,9 6,96 5.856
4 × 1.5 RE 57,60 16,1 1,16 365
4 × 2.5 RE 96,00 17,0 1,27 429
4 × 4 RE 153,60 18,0 1,38 515
4 × 6 RE 230,40 19,2 1,54 628
4 × 10 RE 384,00 21,1 1,77 839
4 × 16 RM 614,40 24,3 2,19 1.210
4 × RM 25 960,00 28,1 2,85 1.717
4 × 35 RM 1.344,00 31,0 3,29 2.209
4 × 50 RM 1.920,00 35,1 4,21 2.921
4 × RM 70 2.688,00 40,0 5,20 3.980
4 × RM 95 3.648,00 45,2 6,56 5.321
4 × 120 RM 4.608,00 49,0 7,38 6.475

Contact us for more information about our products and to request tailor-made cable and raw material solutions for your needs.