Contact us
Follow Us

Nord Group

We offer the widest range of products and services to all our local and global customers

Contact

Address
Merkez Mahallesi Hasat Sokak Kamara Plaza No:52/1 Sisli / Istanbul / Turkey
Telephone
+90 212 963 13 38
+90 212 963 13 41
Email
info@nordgroup.com.tr
Page title icon

NA2XS2Y - XLPE Insulated Single Core Cable with PE Sheath (6/10 kV, 12/20 kV, 18/30 kV)

Untitled-1 copy

NA2XS2Y - XLPE Insulated Single Core Cable with PE Sheath (6/10 kV, 12/20 kV, 18/30 kV)

NA2XS2Y | XLPE Insulated Single Core Cable - PE Sheathed (6/10 kV, 12/20 kV, 18/30 kV)

Product Descriptions

It is designed for installation directly into the ground, indoors and outdoors and in cable ducts.

Structure

  • Multi-stranded (RM) aluminum conductor
  • Inner semiconductor layer
  • Core insulation: Cross-linked polyethylene (XLPE)
  • Outer semiconductor layer
  • Screen: Copper wires
  • Outer sheath: Black polyethylene (PE)

Standards

  • DIN VDE 0276-620 - HD 620 S1:1995 - DIN EN 60228 Class 2

Technical Data

Test Voltage / Duration:

  • 6/10 kV → 21 kV/5 min
  • 12 / 20 kV → 42 kV / 5 min
  • 18/30 kV → 63 kV/5 min

Temperature Range:

  • Both mobile and stationary: -20 °C ... +70 °C
  • Short Circuit Operating Temperature: 250 °C
  • Short Circuit Time (max.): 5 s
  • Bend Radius (min., diameter ×): 15
  • Flame Resistance Standard: EN 60332-1-2
6/10 kV
Cross section (mm²) Aluminum (kg/km) Copper (kg/km) Ø aprox. (mm) Ø max. (mm) Weight (kg/km) Earth Current (A) Air Flow (A)
1×35 RM/16 103 182,4 23 28 600 145 153
1×50 RM/16 147 182,4 24 29 670 171 183
1×70 RM/16 206 182,4 26 31 770 208 228
1×95 RM/16 279 182,4 27 32 880 248 278
1×120 RM/16 353 182,4 29 34 950 283 321
1×150 RM/25 441 283,2 30 35 1150 315 364
1×185 RM/25 544 283,2 32 37 1250 357 418
1×240 RM/25 706 283,2 34 39 1500 413 494
1×300 RM/25 882 283,2 36 41 1700 466 568
1×400 RM/35 1176 393,6 40 45 2100 529 660

 

12/20 kV
Cross section (mm²) Aluminum (kg/km) Copper (kg/km) Ø aprox. (mm) Ø max. (mm) Weight (kg/km) Earth Current (A) Air Flow (A)
1×50 RM/16 147 182,4 28 33 820 172 185
1×70 RM/16 206 182,4 30 35 930 210 231
1×95 RM/16 279 182,4 31 36 1 050 251 280
1×120 RM/16 353 182,4 33 38 1 150 285 323
1×150 RM/25 441 283,2 34 39 1 350 319 366
1×185 RM/25 544 283,2 36 41 1 500 361 420
1×240 RM/25 706 283,2 39 44 1 750 417 496
1×300 RM/25 882 283,2 41 46 2 000 471 569
1×400 RM/35 1176 393,6 44 49 2 350 535 660

 

18/30 kV
Cross section (mm²) Aluminum (kg/km) Copper (kg/km) Ø aprox. (mm) Ø max. (mm) Weight (kg/km) Earth Current (A) Air Flow (A)
1×50 RM/16 147 182,4 33 38 1100 174 187
1×70 RM/16 206 182,4 35 40 1200 213 232
1×95 RM/16 279 182,4 36 41 1350 254 282
1×120 RM/16 353 182,4 38 43 1450 289 325
1×150 RM/25 441 283,2 39 44 1700 322 367
1×185 RM/25 544 283,2 41 46 1850 364 421
1×240 RM/25 706 283,2 43 48 2050 422 496
1×300 RM/25 882 283,2 46 51 2350 476 568
1×400 RM/35 1176 393,6 49 54 2800 541 650

Contact us for more information about our products and to request tailor-made cable and raw material solutions for your needs.