Contact us
Follow Us

Nord Group

We offer the widest range of products and services to all our local and global customers

Contact

Address
Merkez Mahallesi Hasat Sokak Kamara Plaza No:52/1 Sisli / Istanbul / Turkey
Telephone
+90 212 963 13 38
+90 212 963 13 41
Email
info@nordgroup.com.tr
Page title icon

JE-H(ST)H E30...Bd - Halogen Free and Flame Retardant Industrial Electronic Wiring Cable

Untitled-1 copy

JE-H(ST)H E30...Bd - Halogen Free and Flame Retardant Industrial Electronic Wiring Cable

JE-H(ST)H E30...Bd | Halogen Free and Flame Retardant Industrial Electronic Installation Cable (30 Minutes Circuit Integrity)

Product Descriptions

Implementation:

Suitable for fixed installations in telecommunication and industrial electronic installations. It is used in projects where insulation integrity must be maintained for at least 180 minutes and circuit integrity must be maintained for at least 30 minutes in fire risk environments.

Information:

These cables meet the test requirements of 180 minutes insulation integrity according to DIN VDE 0472-814/8.83 and 30 minutes circuit integrity according to IEC Publ. 331 (1970) and DIN 4102-12 (VDE 0100-710/-718) and 30 minutes circuit integrity test requirements.

Structure

  • Solid bare copper conductor
  • Core isolation Halogen-free ceramic-like copolymer
  • Conductors are twisted in groups of two and four star-quad groups
  • Groups are identified by the helical Z mark or ring mark on the insulation
  • Plastic foil sheet
  • Static screen Plastic coated metal foil + 0.8 mm tarred drainage wire
  • Outer sheath: Halogen-free polymer (HM 2), orange color

Standards

  • DIN VDE 0815 (conductor color coding) - DIN EN 60228 Class 1 - DIN VDE 0207-24
  • Technical Data
  • Peak Operating Voltage [V]: 225
  • Temperature Range:
  • Movable: -5 °C ... +50 °C
  • Constant: -30 °C ... +70 °C
  • Bending Radius (according to diameter): 7.5 × diameter
  • Flame Resistance Standard: EN 50266-2-4 - EN 60332-1 - IEC 60332-3 Cat. C
  • Insulation Resistance (min.) [MΩ-km]: 100
  • Mutual Capacity (max.) [nF/km]: 120
  • Capacity Unbalance 100 m (max.) [pF]: 200
Number of Cores and Nominal Diameter (mm) Copper Quantity (kg/km) Insulation Thickness (mm) Outer Diameter (mm) Calorific Potential (kWh/m) Weight (kg/km)
2 × 2 × 0,8 24,00 1,0 6,6 0,13 86
4 × 2 × 0,8 43,20 1,0 8,8 0,20 138
8 × 2 × 0,8 81,60 1,2 12,8 0,34 220
12 × 2 × 0,8 120,96 1,2 13,5 0,39 298
20 × 2 × 0,8 197,76 1,4 16,1 0,53 465
32 × 2 × 0,8 326,40 1,4 20,6 0,85 704

Contact us for more information about our products and to request tailor-made cable and raw material solutions for your needs.